Page 65 - CONSTRUCCIÓN DE ATAJADOS ENLA MICRO REGIÓN DE LA CUENCA RÍO SANTA ANA
P. 65
ESTUDIO TESA
“CONSTRUCCIÓN DE ATAJADOS Y OBRAS DE ALMACENAMIENTO DE AGUA EN LA MICRO
REGIÓN DE LA CUENCA ALTA DEL RIO SANTA ANA”
OTN-PB
Altura obra [m.s.n.m.] = 2406
ATAJADO 1 Area cuenca aporte obra [Km2] = 0.05475
Tipo de suelo Praderas Pendiente [%] = 13.4
Coef.
Área Vol. Esc.
Mes hmín hmín*0.8 Dias/Mes Esc. (C Qm (m3/s) Qm (l/s)
(m2) (M3)
)
Ene 116.77 93.42 31 54750 0.4 2045.82 0.000764 0.7638
Feb 97.03 77.62 28 54750 0.4 1699.91 0.000703 0.7027
Mar 55.18 44.15 31 54750 0.4 966.78 0.000361 0.3610
Abr 14.80 11.84 30 54750 0.4 259.24 0.000100 0.1000
May 1.18 0.00 31 54750 0.4 0.00 0.000000 0.0000
Jun 1.03 0.00 30 54750 0.4 0.00 0.000000 0.0000
Jul 0.71 0.00 31 54750 0.4 0.00 0.000000 0.0000
Ago 1.86 0.00 31 54750 0.4 0.00 0.000000 0.0000
Sep 2.66 0.00 30 54750 0.4 0.00 0.000000 0.0000
Oct 19.05 15.24 31 54750 0.4 333.80 0.000125 0.1246
Nov 50.07 40.06 30 54750 0.4 877.23 0.000338 0.3384
Dic 76.11 60.89 31 54750 0.4 1333.39 0.000498 0.4978
Anual 670.0 536.03 365 54750 0.4 7516.17 0.000238 0.2383
Fuente: Elaboración propia, septiembre 2014.
Ver el detalle de cálculo en anexos (estudio de hidrología).
Para el caso de los caudales aforados (Específicamente para los estanques) se realizó las
mediciones del caudal en el mes más crítico obteniendo de esta manera el caudal para
cada obra y de este caudal medido se consideró el 50% como medida de seguridad.
Para la estimación de caudales medios mensuales y anuales para los estanques se tiene:
Dónde:
3
V ver: Volumen canal (m )
Q ver: Caudal canal (l/s)
t: Tiempo (s)
Con el dato aforado del caudal en el mes más crítico se tiene el siguiente cálculo para el
estanque 1 de la comunidad de San Sebastián:
55
OFICINA TECNICA DE RIOS PÍLCOMAYO Y BERMEJO Elaboración:
Empresa
Consultora Constructora
RIO NUEVO